• Waste Incineration Flue Gas CO2 Capture Sphelite ASD-35 Primary Amine Resin Beads
Waste Incineration Flue Gas CO2 Capture Sphelite ASD-35 Primary Amine Resin Beads

Waste Incineration Flue Gas CO2 Capture Sphelite ASD-35 Primary Amine Resin Beads

Product Details:

Place of Origin: China
Brand Name: SPHLITE
Model Number: ASD-35

Payment & Shipping Terms:

Minimum Order Quantity: 1 Ton
Price: Negotiable
Packaging Details: 25 kg/bag, 40 bags = 1 ton on pallet (custom packaging available)
Delivery Time: 10 working days after payment
Payment Terms: T/T, L/C
Supply Ability: 24000 Tons per Year
Get Best Price Chat Now

Detail Information

Application: Waste Incineration Flue Gas CO2 Capture Typical Feed CO2 Content: 8-12 % After Acid Gas Scrubbing
Position In Train: Downstream Of Acid Gas And Dust Removal Regeneration: Low Temperature Steam Or Hot Inert Gas
Appearance: Maple Opaque Spherical Beads Matrix: Crosslinked Polystyrene, Macroporous
Functional Group: Primary Amine Particle Size Range: 0.35-1.20 Mm
Moisture Content: 58 +/- 5 % Shipping Weight: 0.68 +/- 0.05 G/ml
Coefficient Uniformity: <= 1.5 Temperature Resistance: 100 C
Toxicity: Harmless Packing: 25 Kg/bag, 40 Bags = 1 Ton Per Pallet
Highlight:

Waste Incineration CO2 Capture Resin

,

Macroporous Primary Amine Beads

,

Low Regeneration Energy Resin

Product Description

Sphelite ASD-35 Primary Amine Resin for Waste Incineration Flue Gas CO2 Capture

Waste to energy plants already recover energy from mixed municipal waste, yet their flue gas still carries 8-12 % CO2 and the plant usually sits inside a city where every tonne of carbon counts. Sphelite ASD-35 is a macroporous primary amine resin on a crosslinked polystyrene matrix that captures CO2 from the cleaned flue gas downstream of the acid gas scrubber, turning an existing stack into a carbon capture point without a solvent regeneration loop.

Model ASD-35  |  Primary amine functional group  |  Macroporous crosslinked polystyrene matrix  |  Reusable by low temperature regeneration

Application Scope

ASD-35 fits post combustion capture after semi dry or wet acid gas scrubbing, polishing duty where the plant wants a low CO2 stack concentration, and containerised or skid mounted capture units for urban plants with limited plot space. It is also used in waste gasification and refuse derived fuel gas conditioning, where the same resin protects downstream compression and utilisation equipment.

Typical Technical Parameters

Typical CO2 Content8-12 % after acid gas scrubbing
Inlet ConditionsSaturated gas cooled below 60 °C
RegenerationLow temperature steam, no solvent reboiler
AppearanceMaple opaque spherical beads
MatrixCrosslinked polystyrene, macroporous
Functional GroupPrimary amine
Particle Size Range (mm)0.35-1.20
Moisture Content (%)58 ± 5
Shipping Weight (g/ml)0.68 ± 0.05
Coefficient Uniformity (≤)1.5
Temperature Resistance100 °C
ToxicityHarmless

Why ASD-35 Performs Here

Works after acid gas scrubbing

Once HCl and SO2 are removed, the remaining CO2 is captured chemically by the primary amine group, so capture efficiency does not depend on the CO2 partial pressure being high.

Compact footprint

Because the resin needs no solvent sump, reboiler or large absorber column, a waste to energy plant can fit the capture skid into an existing building, which matters when the site is surrounded by housing.

Stable across wet gas

Municipal waste flue gas is saturated with water vapour after scrubbing. ASD-35 keeps its capacity in humid gas and needs no upstream drying step.

Low operating cost

Regeneration heat is far below a 30 % MEA reboiler duty, so the plant keeps more of its steam turbine output and avoids solvent make up and corrosion inhibitor costs.

Packing, Delivery & Service

Standard export packing is 25 kg per bag, 40 bags (1 ton) per pallet, with custom drum or big bag packing available on request. Lead time is about 10 working days after payment, and our technical team supports loading calculations, pressure drop estimates and pilot column trials before you scale up.

FAQ

Q1. Which point of the flue gas train should the bed sit in?

A: Install the capture bed after dust removal and acid gas scrubbing, with the gas cooled below 60 °C. That protects the resin from fly ash and keeps the working capacity at its design value.

Q2. Is the resin affected by trace heavy metals?

A: Volatile metals are largely captured upstream in the bag filter and scrubber. With normal operation ASD-35 shows no measurable capacity loss; we can advise on a guard bed if your waste mix is unusual.

Q3. Can we start with a small unit?

A: Yes. Trial quantities from 1 kg are available and many customers validate capture rate and pressure drop on a container sized skid before ordering a full bed.

Specifications above are typical values from routine production and can be adjusted to meet a specific project requirement. Please confirm the working conditions with our technical team before ordering.

Want to Know more details about this product
I am interested in Waste Incineration Flue Gas CO2 Capture Sphelite ASD-35 Primary Amine Resin Beads could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.